Adjustable iPad Stand, Tablet Stand Panyekel.
Fitur:
· Input AC universal / rentang pinuh
· Tahan input surge 300VAC pikeun 5 detik
· Ukuran miniatur sareng profil rendah 1U, beurat rendah
· Perlindungan: Sirkuit pondok / Overload / Overvoltage
· Cooling ku convection hawa bébas
· Taya beban konsumsi kakuatan <0.5W
· Luhurna operasi nepi ka 5000 méter(Catetan6)
· Indikator LED pikeun kakuatan on
· 100% tés ngaduruk-in beban pinuh
· Efisiensi High, umur panjang sareng reliabilitas anu luhur
· Garansi 3 taun
Modél | LRS-50-5 | LRS-50-12 | LRS-50-15 | LRS-50-24 | LRS-50-36 | LRS-50-48 | |
kaluaran | tegangan DC | 5V | 12V | 15V | 24V | 36V | 48V |
Dipeunteun ayeuna | 10A | 4.2A | 3.4A | 2.2A | 1.45A | 1.1A | |
rentang ayeuna | 0~10A | 0~4.2A | 0~3.4A | 0~2.2A | 0~1.45A | 0~1.1A | |
kakuatan dipeunteun | 50W | 50.4W | 51W | 52,8W | 52.2W | 52,8W | |
Ripple & noise | 100mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
tegangan DC ADJ.rentang | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% | |
Kasabaran teganganCatetan.3 | ± 3% | ± 2% | ± 1% | ± 1% | ± 1% | ± 1% | |
Perda garisCatetan.4 | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | |
Perda bebanCatetan.5 | ± 2% | ± 1% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | |
Setup, gugah, tahan waktos | 800ms, 30ms, 30ms/230VAC (beban pinuh) | ||||||
asupan | rentang tegangan | 90 ~ 264VAC, 127 ~ 373VDC | |||||
rentang frékuénsi | 47~63HZ | ||||||
arus AC | 0,95A / 115VAC 0,56A / 230VAC | ||||||
Arus asup | Tiis mimiti 45A / 230VAC | ||||||
Efisiensi | 83% | 86% | 87% | 88% | 89% | 90% | |
Arus bocor | <0,75mA/240VAC | ||||||
panyalindungan | overload | Dipeunteun kakuatan kaluaran110% ~ 150% ngamimitian leuwih panyalindungan beban | |||||
tipe panyalindungan: modeu hiccup, recovery otomatis sanggeus kaayaan sesar dihapus | |||||||
Leuwih tegangan | tegangan kaluaran dipeunteun 115% ~ 135% Mimitian leuwih panyalindungan tegangan | ||||||
Jinis panyalindungan: modeu hiccup, pamulihan otomatis saatos kaayaan sesar dipiceun | |||||||
lingkungan | Suhu kerja, kalembaban | -30 ℃ ~ + 70 ℃ (Mangga tingal "kurva derating")20% ~ 90% RH Non-condensing | |||||
Suhu gudang, kalembaban | -40 ℃ ~ + 85 ℃, 10% ~ 95% RH non-condensing | ||||||
Tahan geter | 10 ~ 500HZ, 2G10min / 1 siklus, période pikeun 60 menit, unggal sumbu | ||||||
kaamanan | Tahan tegangan | I/PO/P:3KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | |||||
lalawanan isolasi | I/PO/P,I/P-FG,O/P-FG:100Mohms/500VDC | ||||||
Pas standar | Standar kaamanan | Patuh kana UL60950-1, TUV EN60950-1, GB4943 | |||||
émisi EMC | Patuh kana EN55032(CISPR22)Kelas A,GB9254 Kelas B,EN55014,EN61000-3-2,3 | ||||||
kekebalan EMC | Patuh kana EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-1 | ||||||
batur | Diménsi | 99 * 82 * 30mm (L * W * H) | |||||
Beurat / bungkusan | 0.21kg/60pcs/13.6kg/0.025m³/0.88CUFT | ||||||
MTBF | ≥630K jam mnt.MIL-HDBK-217F(25 ℃) | ||||||
Catetan | 1. Sadaya parameter NOT husus disebutkeun diukur dina input 230VAC, dipeunteun beban sarta 25 ℃ tina hawa ambient. 2. Ripple & noise diukur dina 20MHz rubakpita ku ngagunakeun 12″ twisted pasangan-kawat terminated ku 0.1uf & 47uf kapasitor paralel. 3. Toleransi: ngawengku nyetél kasabaran, pangaturan garis jeung pangaturan beban. Perda 4.Line diukur tina garis low ka garis luhur dina dipeunteun beban. 5.Regulasi beban diukur tina 0% ka 100% dipeunteun beban 6. Suhu ambient derating of 5 ℃ / 1000 m anu diperlukeun pikeun jangkungna operasi leuwih gede ti 2000m (6500ft) 7. The catu daya dianggap salaku komponén nu bakal dipasang kana finalequipment.The parabot final kudu ulang dikonfirmasi yén éta kénéh meets EMC directives.For hidayah on kumaha ngalakukeun tés EMC ieu. |